World Precision Instruments Biological Signals Amplifier Manuel d'instructions

Naviguer en ligne ou télécharger Manuel d'instructions pour Amplificateurs audio World Precision Instruments Biological Signals Amplifier. World Precision Instruments Biological Signals Amplifier Instruction manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 48
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
INSTRUCTION MANUAL
Serial No._____________________
040214
World Precision Instruments
www.wpiinc.com
SI-MT/SI-MKB/SI-HTB
Signal Conditioning Amplifi er System for Muscle Testers
Vue de la page 0
1 2 3 4 5 6 ... 47 48

Résumé du contenu

Page 1 - SI-MT/SI-MKB/SI-HTB

INSTRUCTION MANUALSerial No._____________________040214World Precision Instrumentswww.wpiinc.comSI-MT/SI-MKB/SI-HTBSignal Conditioning Amplifi er Syste

Page 2 - Biofluorometer

SI-H Muscle Testers6WORLD PRECISION IN STRU MENTSNOTE: The 16 plugs marked with A or B are for future development. They are not used at this time.SI-B

Page 3 - CONTENTS

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS7Front PanelZero ButtonGain SwitchData Acquistion OutputForce Transducer ConnectionOffset Adjustment S

Page 4

SI-H Muscle Testers8WORLD PRECISION IN STRU MENTSData Acquisition Output–Connect a data acquisition system like WPI’s Lab-Trax-8/16 to this BNC conne

Page 5 - ABOUT THIS MANUAL

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS9Pulser Port–Connect the Pulser cable to this port when you need to calibrate the system for a force

Page 6 - INTRODUCTION

SI-H Muscle Testers10WORLD PRECISION IN STRU MENTSA red laser diode (=650nm) is used. A one-dimensional (linear) CCD camera with a time resolutio

Page 7

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS11the shorter sarcomeres superimposed on the lines of the longer sarcomeres. This provides a qualitati

Page 8 - INSTRUMENT DESCRIPTION

SI-H Muscle Testers12WORLD PRECISION IN STRU MENTSLCD Display–Upon startup, this display shows the version of the software the SI-SARCAM is running. D

Page 9

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS13Fig. 14 The Linear Motor is an optional part for the SI-MT or SI-MKB systems.The position of the l

Page 10 - SI-H Muscle Testers

SI-H Muscle Testers14WORLD PRECISION IN STRU MENTSFront PanelPosition InPortPosition OutPortPower LEDMotor ConnectionPortFig. 15 The Linear Motor Con

Page 11

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS15 SI-TCM2BThe SI-H Temperature Control Unit is designed for use with the SI-H line of muscle physiol

Page 12

SI-H Muscle TestersIIWORLD PRECISION IN STRU MENTSOther Popular WPI ProductsThe new SI-BF-100 is an LED-based fl uorometer for life science application

Page 13

SI-H Muscle Testers16WORLD PRECISION IN STRU MENTSConfi guration Buttons–The Display button is used to toggle the display between Channel 1 temperature

Page 14

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS17In constant load experiments, the initial length of the muscle is set using the manual adjustments o

Page 15

SI-H Muscle Testers18WORLD PRECISION IN STRU MENTS• Constant Load–This mode maintains a constant load on the tissue sample. CL Commandreceives Fmeasu

Page 16

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS19the motor so that the sarcomere length is held constant while trying to study true isometric contrac

Page 17

SI-H Muscle Testers20WORLD PRECISION IN STRU MENTSStretch Control Knob–This 12-position dial adjusts the response time of the stretch and slack period

Page 18

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS21Connecting the Signal Conditioning Amplifi er SystemFig. 20 Connect the system as shown above.1. Co

Page 19

SI-H Muscle Testers22WORLD PRECISION IN STRU MENTS• IF the SI-BAM21-LCB transducer amplifi er module and the SI-AOSUB anti-oscillation module are not c

Page 20

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS23Constant Load External Loop BypassExt CmdCL (toggle switch–down position)EXT CMD (toggle switch–up p

Page 21

SI-H Muscle Testers24WORLD PRECISION IN STRU MENTSOPERATING INSTRUCTIONS Turning the System OnFor convenience, the Signal Conditioning Amplifi er Syste

Page 22

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS251. Setting a zero reference point with the force transducer un-loaded.2. Applying a load with a kn

Page 23

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTSiiiCopyright © 2014 by World Precision Instruments, Inc. All rights reserved. No part of this publicat

Page 24

SI-H Muscle Testers26WORLD PRECISION IN STRU MENTS CalibrationStandForce Transducer AssemblyTissueMountingHookFig. 21 When the force transducer is pr

Page 25

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS278. If you intend to use multiple amplifi cation factors, cross-check your calibration. For example,

Page 26

SI-H Muscle Testers28WORLD PRECISION IN STRU MENTS Fig. 22 (Left) This pulser assembly has no force transducer mounted in it.Fig. 23 (Right) A fo

Page 27

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS296. Continue to rotate the calibration screw of the Anti-oscillation Frequency Adjustment potentiome

Page 28 - OPERATING INSTRUCTIONS

SI-H Muscle Testers30WORLD PRECISION IN STRU MENTS5. Press the Display button to save the confi guration and return to the normal display. NOTE: The un

Page 29

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS31Adjusting the CCD OffsetCAUTION: The CCD offset should not be modifi ed from the factory default of

Page 30

SI-H Muscle Testers32WORLD PRECISION IN STRU MENTSSetting the Camera (CCD) Mode1. Press the Setup button until “ CCD Mode" displays. Two options

Page 31

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS33SI-SARCAM Front SI-SARCAM BackLaserAVOID EXPOSURELaser radiation emitted from this aperatureAvoid di

Page 32

SI-H Muscle Testers34WORLD PRECISION IN STRU MENTS Fig. 33 (Left) The sarcomere grating fi ts into the cuvette and provides a foolproof calibration

Page 33

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS352. Adjust the trigger level on the oscilloscope. 3. Connect the Video BNC connector to the analog i

Page 34

SI-H Muscle TestersIVWORLD PRECISION IN STRU MENTSSetting the Tissue Distance ...

Page 35

SI-H Muscle Testers36WORLD PRECISION IN STRU MENTSHeating Indicator–A fl ashing arrow pointing up (↑) indicates that the cuvette is heating. Setup1. T

Page 36

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS37 CH 1 Setpoint 37.0ºC Fig. 39 Press the Up and Down buttons to adjust the Channel 1 Setpoint.2

Page 37 - A Laser Product

SI-H Muscle Testers38WORLD PRECISION IN STRU MENTSEnabling/Disabling the AlarmsBy default the alarms are disabled. When enabled, the unit will emit a

Page 38

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS39MAINTENANCEThe Signal Conditioning Amplifi er System is maintenance free. However, to protect it, fo

Page 39

SI-H Muscle Testers40WORLD PRECISION IN STRU MENTSTROUBLESHOOTINGIssue Possible Cause SolutionChassis has no powerOne of the two power switches is of

Page 40

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS41SPECIFICATIONSThis instrument conforms to the following specifi cations:ChassisMaximum Power Consumpt

Page 41 - Min=1 4 Max=8

SI-H Muscle Testers42WORLD PRECISION IN STRU MENTS

Page 42

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS43INDEXSymbols500216-G ii500217 ii500217-G iiAalarm 15, 37amplifi er 6amplitude 9analog voltage

Page 43 - ACCESSORIES

SI-H Muscle Testers44WORLD PRECISION IN STRU MENTSWARRANTYWPI (World Precision Instruments, Inc.) warrants to the original pur chas er that this equip

Page 44 - TROUBLESHOOTING

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS1ABOUT THIS MANUALThe following symbols are used in this guide:This symbol indicates a CAUTION. Cautio

Page 45 - SPECIFICATIONS

SI-H Muscle Testers2WORLD PRECISION IN STRU MENTSFig. 3 The Signal Conditioning Amplifi er System is a fl exible chassis that is specifi cally confi gure

Page 46

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS3FeaturesThis Signal Conditioning Amplifi er System offers eight expansion slots, confi gured at the fac

Page 47

SI-H Muscle Testers4WORLD PRECISION IN STRU MENTSINSTRUMENT DESCRIPTIONSignal Conditioning Amplifi er for the SI-MT/SI-MKB/SI-HTBFront PanelPower Switc

Page 48 - WARRANTY

SI-MT/SI-MKB/SI-HTBWORLD PRECISION IN STRU MENTS5Temperature Control Module–When temperature control is required, the SI-TCM2 is used. It can control

Commentaires sur ces manuels

Pas de commentaire